BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Pinnacle X-Ray Solutions - ECPv6.16.4.1//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:Pinnacle X-Ray Solutions
X-ORIGINAL-URL:https://pxsinc.com
X-WR-CALDESC:Events for Pinnacle X-Ray Solutions
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:UTC
BEGIN:STANDARD
TZOFFSETFROM:+0000
TZOFFSETTO:+0000
TZNAME:UTC
DTSTART:20220101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;VALUE=DATE:20231016
DTEND;VALUE=DATE:20231021
DTSTAMP:20230615T175849Z
CREATED:20230613T205702Z
LAST-MODIFIED:20230615T175849Z
UID:5345-1697414400-1697846399@pxsinc.com
SUMMARY:40 hr DR Level 2 (CR & DDA)
DESCRIPTION:Overview\nThis is a 40 hour (5 day) course developed for currently certified Level 2 personnel transitioning from Film to Non-Film to meet the minimum formal training requirements per NAS410. With Level 3 approval this class may also be used to transition currently certified RT/Film Level 2 personnel to “CR” or “DR” techniques per the requirements of SNT-TC-1A. This class will consist of formal training using lecture\, visual aids\, open discussion\, quizzes\, and hands on experience. \n\nDigital Radiography Overview\nImage Quality Parameters\nDigital Radiography System Components\nImage Fidelity Attributes\nImage Processing\nDetector Attributes\nImage Display Monitor Characteristics\nViewing Environment\nDR Techniques (CR&DDA)\nImage Interpretation\nProcess Controls (System Baseline & Degradation Monitoring)\nEquipment Maintenance\nStandards\, Codes\, and Procedures for Radiography\n\nASNT NDT Level II Certification Requirements
URL:https://pxsinc.com/events/40-hr-dr-level-2-cr-dda/
LOCATION:Pinnacle X-Ray Solutions\, 2205 Northmont Pkwy\, Duluth\, GA\, 30096\, United States
CATEGORIES:Classes
ATTACH;FMTTYPE=image/jpeg:https://pxsinc.com/wp-content/uploads/2023/04/trainingticket_pinnacle.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;VALUE=DATE:20230522
DTEND;VALUE=DATE:20230527
DTSTAMP:20230613T205950Z
CREATED:20230613T205251Z
LAST-MODIFIED:20230613T205950Z
UID:5338-1684713600-1685145599@pxsinc.com
SUMMARY:40 hr DR Level 3 (CR & DDA)
DESCRIPTION:Overview\nThis is a 40 hour (5 day) course developed for currently certified Level 3 personnel transitioning from Film to Non-Film to meet the minimum formal training requirements per NAS410. This class will consist of formal training using lecture\, visual aids\, open discussion\, quizzes\, and hands on experience. \n\nGeneral overview of Industrial Digital Radiography\nCommon Digital System Elements and Image Properties\nDigital System Components\nData Archive and Retrieval\nDigital System Specific Image processing Topics\nSystem Characteristics\nComputed Radiography Testing\nQualification of CR Systems\nDigital Detector Array Testing\nDigital Detector Arrays\nDetector Selection\nQualification of DR Systems\nDigital Radiography Image Quality Topics\nComputed Tomography Testing\nTechnique Development Considerations\nUse of Digital Reference Radiographs\n\nASNT NDT Level III Certification Requirements \n 
URL:https://pxsinc.com/events/40-hr-dr-level-3-cr-dda/
LOCATION:Pinnacle X-Ray Solutions\, 2205 Northmont Pkwy\, Duluth\, GA\, 30096\, United States
CATEGORIES:Classes
END:VEVENT
END:VCALENDAR